Or or p3 earth ground fault to circuit ground. Type of jack to be installed by the telephone company.
E8aefd Fire Relay Module Wiring Diagram Wiring Library
Silent knight 5207 wiring diagram. For specific information regarding sensor spacing placement and special applications refer to nfpa 72 or the system smoke detector applica tion guide available from silent knight. Silent knight swift instructional manual for wsk heat. Compatible modules manufactured by silent knight model what it does 4180 status displayrelay module for remote annunciation of alarm and trouble status information for each zone. You must be in step programming mode also known as mode 27 to program the panel. 71 using step programming enter step programming mode press followed by the code that has been programmed as code 0 the. Function keystrokes system test 0 enter reset alarms or smoke detectors 1 enter clear alarm memory 2 enter reset dialer 3.
5210 zone expander adds 8 zones to the 5207. Silent knight sk basic commands. Silent knight recommends spacing sensors in compliance with nfpa 72. Model 5207 fire alarm built in touchpad operating instructions these instructions must be framed and displayed next to the model 5207 panel in accordance with nfpa 72 fire code for local protected fire alarm systems. Ske 300 series voice evacuation system overview. In low air flow applications with smooth ceilings space sensors 30 feet apart 91 m.
The silent knight sk 300 series is a line of voice evacuation products suitable for use with silent knights model 5204 and 5207 fire controlcommunicators. Rj31x warning this device has been verified to comply with fcc rules part 15. Addressable fire alarm control panel. Operator silence alarms 7 enter user code 7 enter. The sk 5208 is a microprocessor based control panel with integrated ul listed communicator designed for applications requiring smoke detection manual pull stations and sprinkler supervision. 26092018 26092018 1 comments on silent knight 5207 wiring diagram.
151204 1 1 section 1 introduction the model sk 5208 is an 24 volt 10 zone fire alarm control panel expandable up to 30 zones using sk 5217 zone expanders with a digital communicator that meets nfpa 72 requirements. Silent knight swift instructional manual for wsk relay. Addressable fire alarm control panel. For a total expansion of the system to. See the following sections for details. Operation is subject to the.
Silent knight security systems b. The model 5230 remote annunciator is for programming the 5207 panel. Silent knight 5207 wiring diagram. The following silent knight modules used with the model 5207 panel. Sk 2 and sk 4 conventional facp 2 4 zone manual. 11 system overview figure 11 a.