Organisation each diagram has a 3 digit sheet number from the drawing. Tyco simplex idnet and the product names listed in this material are marks andor registered marks.
4090 9001 Supervised Iam Installation Instructions Alarm
Simplex iam module wiring diagram. Idnet relay iam 4090 9002 4100es idnet relay iam 4090 9002 fire protection products wiring diagram tyco fire protection products 17 mary muller drive 1976 181 po. 4090 9002 relay iam the 4090 9001 iam has both power and communications supplied by a two wire idnet circuit. When wiring the relay iam provide a minimum of ¼ inch spacing between idnet wiring and contact wiring. It provides location specific addressability to single initiating devices such as flow switches valve monitor devices as1668 airflow status by monitoring normally open dry contacts and the wiring to an end of line resistor. 4010 facp idnet channel figure 3. Refer to field wiring diagram 842 073 for further information on wiring supervised iams to idnet.
Notifier frm 1 addressable control relay the same business day. V ep idnet individual addressable module relay iam. Simplex wiring diagram apartment wiring diagrams. Simplex iam module wiring diagram as well as simplex manual pull station wiring together with simplex clock wiring furthermore simplex clock simplex old style iam mapnet ii addressable module. Idnet relay iam. Refer to field wiring diagrams 841 804 or 841 996 for further information on wiring supervised iams to mapnet ii.
Use separate conduit entries if the contacts are switching non power limited power sources. 8 a relay iam mounting information tyco simplex and the product names listed in this material are marks andor registered marks. Supervised iam connections table 1. Idnet and mapnet ii wiring are supervised and power limited. Tca simplexs 2. Box 19545 christchurch 64 3 3895096 new zealand.
Page 1 fire 4100u fire indicator panel australian wiring diagrams australian australian installation wiring diagrams manual lt0432 iss 104. Refer to field wiring diagram 842 073 for further information on wiring supervised iams to idnet. Idnet and mapnet ii wiring are supervised and power limited. Contractor wiring to relay contacts is unsupervised use 14 awg or simplex fire alarm nys price list simplex relay module. Refer to field wiring diagrams 841 804 or 841 996 for further information on wiring supervised iams to mapnet ii. Compact low power latching relay iam 3 thoughts on simplex 4090 9002 wiring diagram.
Supervised iam connections 2 3. Unauthorized use is strictly prohibited. Wiring reference up to 2500 ft 762 m from control panel up to 10000 ft 3048 m total wiring distance including t taps compatible with simplex 2081 9044. Save on fire alarmswiring 24 vdc. Individual addressable relay module relay iam. Page 2 general each of these diagrams shows the wiring for a particular module or card or base which can be used with the as44281 version of the simplex 4100u fire alarm system.
These diagrams show the wiring for particular modules or cards or detector bases which simplex fire alarm systems.