Simplex idnet addressable modules provide addressability to conventional devices such as flow switches. 24 point graphic io module.
Simplex Safelinc 4100u Manuals Manualslib
Simplex control module wiring diagram. Screw terminals for inout wiring 18 to 14 awg wire 082 to 208 mm2 idnet communications wiring reference up to 2500 ft 762 m from control panel up to 10000 ft 3048 m total wiring distance including t taps compatible with simplex 2081 9044 overvoltage protectors dimensions 4 ⅛ h x 4 w x 1 ⅜ d 105 mm x 102 mm x 35 mm. Refer to field wiring diagram 842 073 for further information on wiring supervised iams to idnet. Field wiring diagram for 4100 power limited 841 731 or. Box 19545 christchurch 64 3 3895096 new zealand. Field wiring diagram for 4100 power limited 841 731 or field wiring diagram for 4100 non power limited 841 995 4100es fire alarm system installation guide 574 848 this publication discusses the following topics. Unauthorized use is strictly prohibited.
Simplex zone addressable module es fire indicator panel australian wiring diagrams australian wiring diagrams lt iss each of these diagrams shows the wiring for a particular module or card or base which can be used with the as version of the simplex u and es fire alarm systems. Use separate conduit entries if the contacts are switching non power limited power sources. Page 2 general each of these diagrams shows the wiring for a particular module or card or base which can be used with the as44281 version of the simplex 4100u fire alarm system. Upon unpacking your simplex product inspect the contents of the carton for shipping damage. If damage is apparent immediately file a claim with the carrier and notify your local simplex product supplier. Topic see page cautions and warnings 2 setting card the address switch 3.
When wiring the relay iam provide a minimum of ¼ inch spacing between idnet wiring and contact wiring. Lt u fire indicator panel australian wiring diagrams. The 4090 9001 supervised individual addressable module iam provide four state status information normal open current limited and short to the 4008 4010 4010es 4100u and 4100es fire alarm control panel. Simplex wiring diagram ebook 1 phase simplex control panel for grinder and vortex pumps november 26th 1 phase simplex control panel for grinder and vortex simplex individual addressable relay module november 28th buy simplex individual addressable module online from life safety consultants. Idnet module 4100 3101 4100es idnet loop card wiring fire protection products wiring diagram tyco fire protection products 17 mary muller drive 1976 181 po. Simplex has a wide range of innovative addressable modules including multi point modules modules which permit individual reporting from flow and tamper switches on the same circuit and isolator modules which protect power wiring from short circuits and ground faults.
Organisation each diagram has a 3 digit sheet number from the drawing series 1976 181. Tyco simplex idnet and the product names listed in this material are marks andor registered marks.