The information shown for each control panel includes wiring diagrams and circuit tables. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b.
Fire Prevention How Much Voltage Can My Fire Alarm Panel
Fire alarm control module wiring diagram. An esz is a discrete area of a building bounded by smoke or fire barriers in which occupants are intended to relocate or evacuate. Break wire run to provide supervision. The circuit type is designated with a letter a z. Siga im 70 audio. Box and the control module must be placed into the barrier and at tached to the junction box figure 2a. Addressability al lows the fcm to be activated either manually or through.
2 firelite slc wiring manual pn 51309r2 3192019 fire alarm emergency communication system limitations while a life safety system may lower insurance rates it is not a substitute for life and property insurance. Some control panels have relay built in and do not require external wiring. Level 0 means no survivability is required wiring within the esz level 1 3 indicate that attack by fire shall not impair the control and operation of notification appliances outside the esz. Is recommended 24 vdc circuit 3 4. It shows the components of the circuit as simplified shapes and the capacity and signal associates together with the devices. Fire alarm security access control cctv published by edwards systems technology in conjunction with paige electric co lp.
Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 10. Fcm 1 module see wiring diagram fig. Fire alarm control module wiring diagram wiring diagram is a simplified customary pictorial representation of an electrical circuit. Refer to notifier manual. Siga rel 69 isolator module. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit.
Module polarities are shown in alarm connect modules to listed compatible 32 vdc max. To next control module or end of line relay. Fire alarm system is the combination of different components such as smoke detector heat detector carbon monoxide detector multi sensor detector call points sounders bells relay module repeater annunciator fire control panel and other related and optional security devices designed for fire alarm control system. One relay required for each circuit. An automatic fire alarm systemtypically made up of smoke detectors heat detectors manual pull stations audible warning.