Boyer power box has a capacitor in it. These values are just right for charging a 12 volt battery or running the electrics.
4l60 Lock Up Wiring Diagram Wiring Diagram
Boyer power box wiring diagram. These values are just right for charging a 12 volt battery or running the electrics direct. I just realized that the bsa also had a power box boyer and no battery the wiring diagram i found on the web shows this power unit being if you fax bransden electronics the bransden part of boyer bransden and the. Run the red wire from the ignition box to the positive terminal of the coil. The black wire from the box is shorted to ground. Pbox single phase power box alternator regulator if the light control is required fit the power box type pto. The maximum current draw through the boyer box must not exceed 5 amps.
See appropriate wiring diagram. With a samp load lights off more if lights are wired to come on with ignition switch. If you are using the 5 ohm dyna coil see 12 v dyna coilswiring diagram mounting kit for that wiring diagram. Run the black wire from the ignition box to the negative terminal of the coil. The 5 amp current capacity of the box will be exceeded and the box permanently damaged if. Boyer bransden power box the power box is a self regulating rectifier with an internal current and voltage storing capacitor.
Power box the power box is a self regulating rectifier with an internal current and voltage storing capacitor. 19 connect the white blue wire the one removed from the ballast resistor to the white wire from the transistor box. The black wire between the coils is shorted to ground. Third wire on the alternator is connected to one of the other two see wiring diagram. The coils short internally to ground. To individually check each coil you will need to rewire the boyer box wiring black and red wires so they go to one coil.
0044 01622 730 939. Click here to download the power box instructions pbox00108 and data leaflet in pdf format. Connecting directly to the alternator the output is approximately 15 volts with no current being drawn and 145 volts with some load. 18 connect the black wire from the transistor box to the terminal of the right hand ignition coil. Connecting directly to the alternator the output is approximately 15 volts with no current being drawn and 145 volts with some load. Micro power electronic ignition system for unit triumph or bsa twin fitted with an 18d2 distributor 12v distributor modification required kit00280 box00231 micropower digital ignition system for unit consctruction single cylinder 4 stroke triumph bsa engines with 12 volt electrics and side points 211k.
The earth terminal on the rectifier is normally the centre bolt the wires on this can be bolted back to the chassis along with the red wire if positive earth or black wire if negative earth from the power box.