Suitable for use with c tecs cfp alarmsense range of 2 8 zone two. Will accept any alarmsense fire detector to provide fire detection and an audible alarm warning signal at the same point.

Alarmsense 2 Wire Detection And Alarm System Product Guide
Alarmsense sounder base wiring diagram. Wiring connections to the alarmsense base part no 45681 244 are shown in fig 6. Certified to en54 3 by ul international uk limited. Alarmsense detectors can only be mounted into the alarmsense base. The incoming and outgoing cables are connected to the same terminals l1 in ve line and l2 ve line. The alarmsense optical smoke detector with visual sounder base is part of apollos range of two wire detection and alarm products encompassing both optical and heat detectors in addition to sounder bases and sounder beacon bases a mcp and alarm relay equipment. A remote indicator can be connected to each base r remote led ve and l2 remote led ve.
The incoming and outgoing cables are connected to the same terminals l1 in ve line and l2 ve line. Alarmsense base sounder 45681 510apo alarmsense base sounder 45681 510apo. Suitable for use with c tecs cfp alarmsense range of 2 8 zone two wire fire panels. Apollos fault finding guide suggests that continuous sounders indicate a non alarmsense compatible panel has been used different 2 wire panel or a traditional 4 wire or indeed the conventional sounder circuits instead of the alarmsense zones apollo dont make the panels. Certified to en54 3 by ul international uk limited. Schematic wiring diagram of an alarmsense zone with sounder base as end of line alarmsense alarm relay on 1 2 l1 l2 no 1 com 1 nc 1 nc 2 com 2 no 2 from control panel switch 1 off priority default on non priority switch 2 off no reset delay default on 2 sec reset delay dil switch positions on 1 2.
Alarmsense the alarmsense range of two wire detection and alarm products work via connection to a single pair of supply wires. Fig 1 soundersounder beacon base alarmsense base wiring connections to the alarmsense base part no 45681 244 are shown in fig 4. This benefits both the installer and the end user by making installation easier and quicker less expensive and more adaptable as you do not have to run separate sounder circuits. Alarmsense works via connection to a single pair of supply wires. End of line resistor as recommended by the panel manufacturer. Compatible panels are made by c tec haes and kentec.
The base is used for installing detectors that do not require an integral sounder or sounder visual indicator. Will accept any alarmsense fire detector to provide fire detection and an audible alarm warning signal at the same point. A remote indicator can be connected to each base r remote led ve and l2 remote led ve. With sounder beacon base detector with sounder base manual call point. Alarmsense prioritynon priority signal recognition detects the removal of a detector head and reports a. Do not connect any field wiring to the l1 out terminal of the alarmsense base.
Soundersounder beacon base dil switch position.