4do not over tighten the enclosing tube locknut. Solenoid valves with four wire dual voltage coils have a wiring diagram decal figure 3 on the.
Automatic Valve D2003acwr Dbyap 5 2 Solenoid Valve Ims Supply
Sporlan mkc 1 wiring diagram. Connect power wires to terminals 1 and 2. Transformer requirements are 24 volts ac at 40va class ii. The following is a selection of sporlan references available for download. The solenoid valve operation is based on the theory of the electromagnet. If you would like to receive pricing andor paper copies of literature please contact your sales office or contact sporlan division by phone at 636 239 1111. Standard torque charts do not apply.
Extremely rugged simple design few parts. 12050 60 j a k 30 y connector on end of leadwire b 14 female spade disconnect barrel insulated both wires na c 14 female spade disconnect fully insulated both wires p 14 female spade disconnect fully insulated only on one wire y 14 fork terminal barrel insulated n packard connector metri pak 15300027. All information is in portable document format pdf. 150 150 175 106 216 116 131 1valves with mounting holes use a 8 32 screw torqued not more than 15 in lb. O mkc 1. The 12 bx conduit connection or junction box on the coil may be rotated to any position by loosening the coil hexscrew.
Actual system piping must be done so as to protect the compressor at all times. Class f temperature rating coil types mkc 1 mkc 2 and omkc 2. Standard torque charts do not apply. 3coil housing must not be below horizontal. Race catalogue 30 10 uk page 1 sporlan solenoid valves benefits molded coil for most sizes. E series may be brazed without disassembly.
40 catch all filter driers. 20 refrigerant distributors. 3coil housing must not be below horizontal. Tight closing through use of synthetic seating material. 10 thermostatic expansion valves. Wiring check the electrical specifications of the coil to be sure they correspond to the available electrical service.
Parker sporlan solenoid valves may be applied on a wide variety of air conditioning and refrigeration applications. This includes protection against. 4do not over tighten the enclosing tube locknut. 2coil housing to be no more than 45 from the vertical. 50 isolation valves. Liquid line suction line hot gas etc.
Remove the protective clear film cover from the front of the temperature control. 30 solenoid valves. This principle is used to open the port of the valve by attaching a stem to the magnetic metal or plunger. Can be used with most commercially available cfc hcfc and hfc. 958101 1390 000 coil screw 1 mkc 2 coil mkc 2 coil specify voltage frequency 1 183660 641 3 enclosing tube gasket 1 382150 13252. Connect the sporlan electric valve wires to terminals 5 6 7 and 8 matching the colors shown in the wiring diagram.
Bulletin bulletin 90 40 or other sporlan product literature the sporlan warranty is void. 2coil housing to be no more than 45 from the vertical. 150 150 175 106 216 116 131 1valves with mounting holes use a 8 32 screw torqued not more than 15 in lb.